Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device

Tämä pro gradu-tutkielma koostuu kahdesta osasta. Ensimmäisessä osassa stabiilin ytterbiumin magneettinen oktupolimomentti määritetään kollineaarista laserspektroskopiaa (CLS) ja nopeaa atomisuihkua käyttäen. Mittaus suoritetaan IGISOL-laitteistolla (Ion-Guide Isotope Separator On-Line) Jyväskylän Y...

Full description

Bibliographic Details
Main Author: Kujanpää, Sonja
Other Authors: Matemaattis-luonnontieteellinen tiedekunta, Faculty of Sciences, Fysiikan laitos, Department of Physics, Jyväskylän yliopisto, University of Jyväskylä
Format: Master's thesis
Language:eng
Published: 2020
Subjects:
Online Access: https://jyx.jyu.fi/handle/123456789/71283
_version_ 1826225692863365120
author Kujanpää, Sonja
author2 Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics Jyväskylän yliopisto University of Jyväskylä
author_facet Kujanpää, Sonja Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics Jyväskylän yliopisto University of Jyväskylä Kujanpää, Sonja Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics Jyväskylän yliopisto University of Jyväskylä
author_sort Kujanpää, Sonja
datasource_str_mv jyx
description Tämä pro gradu-tutkielma koostuu kahdesta osasta. Ensimmäisessä osassa stabiilin ytterbiumin magneettinen oktupolimomentti määritetään kollineaarista laserspektroskopiaa (CLS) ja nopeaa atomisuihkua käyttäen. Mittaus suoritetaan IGISOL-laitteistolla (Ion-Guide Isotope Separator On-Line) Jyväskylän Yliopiston kiihdytinlaboratoriossa. 173-Yb:n metastabiilin tilan ylihienokertoimet mitataan käyttäen kolmea erilaista optista dipolisiirtymää. Mitatusta ylihienospektristä määritetään dipoli-, kvadrupoli ja oktupolikertoimet joista saadaan vastaavat ytimen momentit ydinteorian avulla. Tutkielman toinen osa tehdään CERN:issä ISOLDE:lla (Isotope Separator On-Line DEvice), jossa kehitetään moniheijastavan lentoaikamassaspektrometrin (MR-ToF) ja CLS:an yhdistävää Multi Ion Reflection Apparatus for CLS (MIRACLS) -laitteistoa. MIRACLS käyttää MR-ToF:ia ioniloukkuna laserin ja ionien välisen vuorovaikutusajan pidentämiseksi. Tästä johtuu populaation pumppautuminen pois kiinnostuksen kohteena olevalta ylihienotilalta, jolloin havaittu fluoresenssi vähenee. Radiotaajuuden (RF) avulla voidaan ajaa siirtymiä, jotka täyttävät vajaan tilan uudelleen, johtaen fluoresenssin ja signaalin palautumiseen. Tätä varten suunnitellaan uusi keskielektrodi MR-ToF-laitteeseen RF-elektrodien kera. This thesis consists of two parts. In the first part, the magnetic octupole moment of stable ytterbium was determined using collinear laser spectroscopy (CLS) on a fast atomic beam in the Ion-Guide Isotope Separator On-Line (IGISOL) facility at Jyväskylä. The hyperfine constants of the metastable state in 173-Yb were measured using three different dipole transitions. From the resulting hyperfine spectra, can the constants for dipole, quadrupole, and octupole, be extracted. The corresponding nuclear moments are determined by combining these constants with nuclear theory calculations. The second part of this thesis was done at CERN, in the Multi Ion Reflection Apparatus for CLS (MIRACLS) experiment located in the Isotope Separator On-Line Device (ISOLDE) facility. MIRACLS uses a Multi Reflection Time-of-Flight (MR-ToF) ion trap to extend the laser-ion interaction time. Using this method, the population of the hyperfine state of interest can be pumped out unintentionally, leading to less fluorescence. It can be avoided by applying an RF field to repopulate that state, which increases fluorescence and boosts signal. A new design for the MR-ToF drift tube with an RF electrode was devised.
first_indexed 2020-07-30T20:00:32Z
format Pro gradu
free_online_boolean 1
fullrecord [{"key": "dc.contributor.advisor", "value": "de Groote, Ruben", "language": "", "element": "contributor", "qualifier": "advisor", "schema": "dc"}, {"key": "dc.contributor.author", "value": "Kujanp\u00e4\u00e4, Sonja", "language": "", "element": "contributor", "qualifier": "author", "schema": "dc"}, {"key": "dc.date.accessioned", "value": "2020-07-30T07:31:43Z", "language": null, "element": "date", "qualifier": "accessioned", "schema": "dc"}, {"key": "dc.date.available", "value": "2020-07-30T07:31:43Z", "language": null, "element": "date", "qualifier": "available", "schema": "dc"}, {"key": "dc.date.issued", "value": "2020", "language": "", "element": "date", "qualifier": "issued", "schema": "dc"}, {"key": "dc.identifier.uri", "value": "https://jyx.jyu.fi/handle/123456789/71283", "language": null, "element": "identifier", "qualifier": "uri", "schema": "dc"}, {"key": "dc.description.abstract", "value": "T\u00e4m\u00e4 pro gradu-tutkielma koostuu kahdesta osasta. Ensimm\u00e4isess\u00e4 osassa stabiilin ytterbiumin magneettinen oktupolimomentti m\u00e4\u00e4ritet\u00e4\u00e4n kollineaarista laserspektroskopiaa (CLS) ja nopeaa atomisuihkua k\u00e4ytt\u00e4en. Mittaus suoritetaan IGISOL-laitteistolla (Ion-Guide Isotope Separator On-Line) Jyv\u00e4skyl\u00e4n Yliopiston kiihdytinlaboratoriossa. 173-Yb:n metastabiilin tilan ylihienokertoimet mitataan k\u00e4ytt\u00e4en kolmea erilaista optista dipolisiirtym\u00e4\u00e4. Mitatusta ylihienospektrist\u00e4 m\u00e4\u00e4ritet\u00e4\u00e4n dipoli-, kvadrupoli ja oktupolikertoimet joista saadaan vastaavat ytimen momentit ydinteorian avulla. \nTutkielman toinen osa tehd\u00e4\u00e4n CERN:iss\u00e4 ISOLDE:lla (Isotope Separator On-Line DEvice), jossa kehitet\u00e4\u00e4n moniheijastavan lentoaikamassaspektrometrin (MR-ToF) ja CLS:an yhdist\u00e4v\u00e4\u00e4 Multi Ion Reflection Apparatus for CLS (MIRACLS) -laitteistoa. MIRACLS k\u00e4ytt\u00e4\u00e4 MR-ToF:ia ioniloukkuna laserin ja ionien v\u00e4lisen vuorovaikutusajan pident\u00e4miseksi. T\u00e4st\u00e4 johtuu populaation pumppautuminen pois kiinnostuksen kohteena olevalta ylihienotilalta, jolloin havaittu fluoresenssi v\u00e4henee. Radiotaajuuden (RF) avulla voidaan ajaa siirtymi\u00e4, jotka t\u00e4ytt\u00e4v\u00e4t vajaan tilan uudelleen, johtaen fluoresenssin ja signaalin palautumiseen. T\u00e4t\u00e4 varten suunnitellaan uusi keskielektrodi MR-ToF-laitteeseen RF-elektrodien kera.", "language": "fi", "element": "description", "qualifier": "abstract", "schema": "dc"}, {"key": "dc.description.abstract", "value": "This thesis consists of two parts. In the first part, the magnetic octupole moment of stable ytterbium was determined using collinear laser spectroscopy (CLS) on a fast atomic beam in the Ion-Guide Isotope Separator On-Line (IGISOL) facility at Jyv\u00e4skyl\u00e4. The hyperfine constants of the metastable state in 173-Yb were measured using three different dipole transitions. From the resulting hyperfine spectra, can the constants for dipole, quadrupole, and octupole, be extracted. The corresponding nuclear moments are determined by combining these constants with nuclear theory calculations. \nThe second part of this thesis was done at CERN, in the Multi Ion Reflection Apparatus for CLS (MIRACLS) experiment located in the Isotope Separator On-Line Device (ISOLDE) facility. MIRACLS uses a Multi Reflection Time-of-Flight (MR-ToF) ion trap to extend the laser-ion interaction time. Using this method, the population of the hyperfine state of interest can be pumped out unintentionally, leading to less fluorescence. It can be avoided by applying an RF field to repopulate that state, which increases fluorescence and boosts signal. A new design for the MR-ToF drift tube with an RF electrode was devised.", "language": "en", "element": "description", "qualifier": "abstract", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Submitted by Paivi Vuorio (paelvuor@jyu.fi) on 2020-07-30T07:31:43Z\nNo. of bitstreams: 0", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Made available in DSpace on 2020-07-30T07:31:43Z (GMT). No. of bitstreams: 0\n Previous issue date: 2020", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.format.extent", "value": "79", "language": "", "element": "format", "qualifier": "extent", "schema": "dc"}, {"key": "dc.format.mimetype", "value": "application/pdf", "language": null, "element": "format", "qualifier": "mimetype", "schema": "dc"}, {"key": "dc.language.iso", "value": "eng", "language": null, "element": "language", "qualifier": "iso", "schema": "dc"}, {"key": "dc.rights", "value": "In Copyright", "language": "en", "element": "rights", "qualifier": null, "schema": "dc"}, {"key": "dc.subject.other", "value": "collinear laser spectroscopy", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "ytterbium", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "magnetic octupole moment", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "IGISOL", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "laser-radiofrequency double-resonance", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "multi reflection time-of-flight", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "MR-ToF", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "CERN", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "ISOLDE", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "MIRACLS", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.title", "value": "Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device", "language": "", "element": "title", "qualifier": null, "schema": "dc"}, {"key": "dc.type", "value": "master thesis", "language": null, "element": "type", "qualifier": null, "schema": "dc"}, {"key": "dc.identifier.urn", "value": "URN:NBN:fi:jyu-202007305431", "language": "", "element": "identifier", "qualifier": "urn", "schema": "dc"}, {"key": "dc.type.ontasot", "value": "Pro gradu -tutkielma", "language": "fi", "element": "type", "qualifier": "ontasot", "schema": "dc"}, {"key": "dc.type.ontasot", "value": "Master\u2019s thesis", "language": "en", "element": "type", "qualifier": "ontasot", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Matemaattis-luonnontieteellinen tiedekunta", "language": "fi", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Faculty of Sciences", "language": "en", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Fysiikan laitos", "language": "fi", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Department of Physics", "language": "en", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "Jyv\u00e4skyl\u00e4n yliopisto", "language": "fi", "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "University of Jyv\u00e4skyl\u00e4", "language": "en", "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Fysiikka", "language": "fi", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Physics", "language": "en", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "yvv.contractresearch.funding", "value": "0", "language": "", "element": "contractresearch", "qualifier": "funding", "schema": "yvv"}, {"key": "dc.type.coar", "value": "http://purl.org/coar/resource_type/c_bdcc", "language": null, "element": "type", "qualifier": "coar", "schema": "dc"}, {"key": "dc.rights.accesslevel", "value": "openAccess", "language": null, "element": "rights", "qualifier": "accesslevel", "schema": "dc"}, {"key": "dc.type.publication", "value": "masterThesis", "language": null, "element": "type", "qualifier": "publication", "schema": "dc"}, {"key": "dc.subject.oppiainekoodi", "value": "4021", "language": "", "element": "subject", "qualifier": "oppiainekoodi", "schema": "dc"}, {"key": "dc.subject.yso", "value": "spektroskopia", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "laserit", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "fysiikka", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "ydinfysiikka", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "spectroscopy", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "lasers", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "physics", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "nuclear physics", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.format.content", "value": "fulltext", "language": null, "element": "format", "qualifier": "content", "schema": "dc"}, {"key": "dc.rights.url", "value": "https://rightsstatements.org/page/InC/1.0/", "language": null, "element": "rights", "qualifier": "url", "schema": "dc"}, {"key": "dc.type.okm", "value": "G2", "language": null, "element": "type", "qualifier": "okm", "schema": "dc"}]
id jyx.123456789_71283
language eng
last_indexed 2025-02-18T10:54:26Z
main_date 2020-01-01T00:00:00Z
main_date_str 2020
online_boolean 1
online_urls_str_mv {"url":"https:\/\/jyx.jyu.fi\/bitstreams\/dc9241bb-8401-466b-b7ea-0a2c7c8b604b\/download","text":"URN:NBN:fi:jyu-202007305431.pdf","source":"jyx","mediaType":"application\/pdf"}
publishDate 2020
record_format qdc
source_str_mv jyx
spellingShingle Kujanpää, Sonja Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device collinear laser spectroscopy ytterbium magnetic octupole moment IGISOL laser-radiofrequency double-resonance multi reflection time-of-flight MR-ToF CERN ISOLDE MIRACLS Fysiikka Physics 4021 spektroskopia laserit fysiikka ydinfysiikka spectroscopy lasers physics nuclear physics
title Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device
title_full Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device
title_fullStr Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device
title_full_unstemmed Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device
title_short Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device
title_sort determination of the magnetic octupole moment of 173 yb and a design towards laser double resonance methods in an mr tof device
title_txtP Determination of the magnetic octupole moment of 173-Yb and a design towards laser-double resonance methods in an MR-ToF device
topic collinear laser spectroscopy ytterbium magnetic octupole moment IGISOL laser-radiofrequency double-resonance multi reflection time-of-flight MR-ToF CERN ISOLDE MIRACLS Fysiikka Physics 4021 spektroskopia laserit fysiikka ydinfysiikka spectroscopy lasers physics nuclear physics
topic_facet 4021 CERN Fysiikka IGISOL ISOLDE MIRACLS MR-ToF Physics collinear laser spectroscopy fysiikka laser-radiofrequency double-resonance laserit lasers magnetic octupole moment multi reflection time-of-flight nuclear physics physics spectroscopy spektroskopia ydinfysiikka ytterbium
url https://jyx.jyu.fi/handle/123456789/71283 http://www.urn.fi/URN:NBN:fi:jyu-202007305431
work_keys_str_mv AT kujanpääsonja determinationofthemagneticoctupolemomentof173ybandadesigntowardslaserdoubleresonan