Effect of magnetizing voltage frequency on Barkhausen noise signal

Effect of magnetizing frequency on Barkhausen noise signal measurements in dynamic high frequency Barkhausen noise was studied. 100, 250, 500 and 1000 Hz magnetizing frequencies were used in the measurements for three different bearing race samples with several different Barkhausen noise sensors. Sa...

Täydet tiedot

Bibliografiset tiedot
Päätekijä: Ahola, Oskari
Muut tekijät: Matemaattis-luonnontieteellinen tiedekunta, Faculty of Sciences, Fysiikan laitos, Department of Physics, Jyväskylän yliopisto, University of Jyväskylä
Aineistotyyppi: Pro gradu
Kieli:eng
Julkaistu: 2020
Aiheet:
Linkit: https://jyx.jyu.fi/handle/123456789/68594
_version_ 1828193069428637696
author Ahola, Oskari
author2 Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics Jyväskylän yliopisto University of Jyväskylä
author_facet Ahola, Oskari Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics Jyväskylän yliopisto University of Jyväskylä Ahola, Oskari Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics Jyväskylän yliopisto University of Jyväskylä
author_sort Ahola, Oskari
datasource_str_mv jyx
description Effect of magnetizing frequency on Barkhausen noise signal measurements in dynamic high frequency Barkhausen noise was studied. 100, 250, 500 and 1000 Hz magnetizing frequencies were used in the measurements for three different bearing race samples with several different Barkhausen noise sensors. Sampling rate was decreased and sensor surface velocity was increased linearly with the increasing magnetizing frequency. Measurements were successful with all of the used frequencies. However, the background noise was increased with the higher frequencies. Moving average filtering was used for some of the 1000 Hz measurements in order to decrease background noise. Using the moving average filter to 1000 Hz measurement data improved signal-to-noise ratio up to 205% compared to the original 1000 Hz measurement in some cases and 68% compared to the 100 Hz measurement in some cases. Background noise levels were decreased up to 280% in some cases.
first_indexed 2020-04-20T20:01:03Z
format Pro gradu
fullrecord [{"key": "dc.contributor.advisor", "value": "Palosaari, Mikko", "language": "", "element": "contributor", "qualifier": "advisor", "schema": "dc"}, {"key": "dc.contributor.advisor", "value": "Maasilta, Ilari", "language": "", "element": "contributor", "qualifier": "advisor", "schema": "dc"}, {"key": "dc.contributor.author", "value": "Ahola, Oskari", "language": "", "element": "contributor", "qualifier": "author", "schema": "dc"}, {"key": "dc.date.accessioned", "value": "2020-04-20T05:29:36Z", "language": null, "element": "date", "qualifier": "accessioned", "schema": "dc"}, {"key": "dc.date.available", "value": "2020-04-20T05:29:36Z", "language": null, "element": "date", "qualifier": "available", "schema": "dc"}, {"key": "dc.date.issued", "value": "2020", "language": "", "element": "date", "qualifier": "issued", "schema": "dc"}, {"key": "dc.identifier.uri", "value": "https://jyx.jyu.fi/handle/123456789/68594", "language": null, "element": "identifier", "qualifier": "uri", "schema": "dc"}, {"key": "dc.description.abstract", "value": "Effect of magnetizing frequency on Barkhausen noise signal measurements in dynamic high frequency Barkhausen noise was studied. 100, 250, 500 and 1000 Hz magnetizing frequencies were used in the measurements for three different bearing race samples with several different Barkhausen noise sensors. Sampling rate was decreased and sensor surface velocity was increased linearly with the increasing magnetizing frequency. Measurements were successful with all of the used frequencies. However, the background noise was increased with the higher frequencies. Moving average filtering was used for some of the 1000 Hz measurements in order to decrease background noise. Using the moving average filter to 1000 Hz measurement data improved signal-to-noise ratio up to 205% compared to the original 1000 Hz measurement in some cases and 68% compared to the 100 Hz measurement in some cases. Background noise levels were decreased up to 280% in some cases.", "language": "en", "element": "description", "qualifier": "abstract", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Submitted by Paivi Vuorio (paelvuor@jyu.fi) on 2020-04-20T05:29:36Z\nNo. of bitstreams: 0", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Made available in DSpace on 2020-04-20T05:29:36Z (GMT). No. of bitstreams: 0\n Previous issue date: 2020", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.format.extent", "value": "122", "language": "", "element": "format", "qualifier": "extent", "schema": "dc"}, {"key": "dc.format.mimetype", "value": "application/pdf", "language": null, "element": "format", "qualifier": "mimetype", "schema": "dc"}, {"key": "dc.language.iso", "value": "eng", "language": null, "element": "language", "qualifier": "iso", "schema": "dc"}, {"key": "dc.rights", "value": "In Copyright", "language": "en", "element": "rights", "qualifier": null, "schema": "dc"}, {"key": "dc.subject.other", "value": "Barkhausen noise", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "high frequency", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "moving average filtering", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "dynamic measurement", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.title", "value": "Effect of magnetizing voltage frequency on Barkhausen noise signal", "language": "", "element": "title", "qualifier": null, "schema": "dc"}, {"key": "dc.type", "value": "master thesis", "language": null, "element": "type", "qualifier": null, "schema": "dc"}, {"key": "dc.identifier.urn", "value": "URN:NBN:fi:jyu-202004202810", "language": "", "element": "identifier", "qualifier": "urn", "schema": "dc"}, {"key": "dc.type.ontasot", "value": "Pro gradu -tutkielma", "language": "fi", "element": "type", "qualifier": "ontasot", "schema": "dc"}, {"key": "dc.type.ontasot", "value": "Master\u2019s thesis", "language": "en", "element": "type", "qualifier": "ontasot", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Matemaattis-luonnontieteellinen tiedekunta", "language": "fi", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Faculty of Sciences", "language": "en", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Fysiikan laitos", "language": "fi", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Department of Physics", "language": "en", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "Jyv\u00e4skyl\u00e4n yliopisto", "language": "fi", "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "University of Jyv\u00e4skyl\u00e4", "language": "en", "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Soveltava fysiikka", "language": "fi", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Applied Physics", "language": "en", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "yvv.contractresearch.collaborator", "value": "business", "language": "", "element": "contractresearch", "qualifier": "collaborator", "schema": "yvv"}, {"key": "yvv.contractresearch.funding", "value": "2100", "language": "", "element": "contractresearch", "qualifier": "funding", "schema": "yvv"}, {"key": "yvv.contractresearch.initiative", "value": "business", "language": "", "element": "contractresearch", "qualifier": "initiative", "schema": "yvv"}, {"key": "dc.type.coar", "value": "http://purl.org/coar/resource_type/c_bdcc", "language": null, "element": "type", "qualifier": "coar", "schema": "dc"}, {"key": "dc.rights.accesslevel", "value": "restrictedAccess", "language": null, "element": "rights", "qualifier": "accesslevel", "schema": "dc"}, {"key": "dc.type.publication", "value": "masterThesis", "language": null, "element": "type", "qualifier": "publication", "schema": "dc"}, {"key": "dc.subject.oppiainekoodi", "value": "4023", "language": "", "element": "subject", "qualifier": "oppiainekoodi", "schema": "dc"}, {"key": "dc.subject.yso", "value": "magnetismi", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "magnetism", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.format.content", "value": "fulltext", "language": null, "element": "format", "qualifier": "content", "schema": "dc"}, {"key": "dc.rights.url", "value": "https://rightsstatements.org/page/InC/1.0/", "language": null, "element": "rights", "qualifier": "url", "schema": "dc"}, {"key": "dc.rights.accessrights", "value": "The author has not given permission to make the work publicly available electronically. Therefore the material can be read only at the archival workstation at Jyv\u00e4skyl\u00e4 University Library (https://kirjasto.jyu.fi/en/workspaces/facilities).", "language": "en", "element": "rights", "qualifier": "accessrights", "schema": "dc"}, {"key": "dc.rights.accessrights", "value": "Tekij\u00e4 ei ole antanut lupaa avoimeen julkaisuun, joten aineisto on luettavissa vain Jyv\u00e4skyl\u00e4n yliopiston kirjaston arkistoty\u00f6semalta. Ks. https://kirjasto.jyu.fi/fi/tyoskentelytilat/laitteet-ja-tilat..", "language": "fi", "element": "rights", "qualifier": "accessrights", "schema": "dc"}, {"key": "dc.type.okm", "value": "G2", "language": null, "element": "type", "qualifier": "okm", "schema": "dc"}]
id jyx.123456789_68594
language eng
last_indexed 2025-03-31T20:01:03Z
main_date 2020-01-01T00:00:00Z
main_date_str 2020
publishDate 2020
record_format qdc
source_str_mv jyx
spellingShingle Ahola, Oskari Effect of magnetizing voltage frequency on Barkhausen noise signal Barkhausen noise high frequency moving average filtering dynamic measurement Soveltava fysiikka Applied Physics 4023 magnetismi magnetism
title Effect of magnetizing voltage frequency on Barkhausen noise signal
title_full Effect of magnetizing voltage frequency on Barkhausen noise signal
title_fullStr Effect of magnetizing voltage frequency on Barkhausen noise signal Effect of magnetizing voltage frequency on Barkhausen noise signal
title_full_unstemmed Effect of magnetizing voltage frequency on Barkhausen noise signal Effect of magnetizing voltage frequency on Barkhausen noise signal
title_short Effect of magnetizing voltage frequency on Barkhausen noise signal
title_sort effect of magnetizing voltage frequency on barkhausen noise signal
title_txtP Effect of magnetizing voltage frequency on Barkhausen noise signal
topic Barkhausen noise high frequency moving average filtering dynamic measurement Soveltava fysiikka Applied Physics 4023 magnetismi magnetism
topic_facet 4023 Applied Physics Barkhausen noise Soveltava fysiikka dynamic measurement high frequency magnetism magnetismi moving average filtering
url https://jyx.jyu.fi/handle/123456789/68594 http://www.urn.fi/URN:NBN:fi:jyu-202004202810
work_keys_str_mv AT aholaoskari effectofmagnetizingvoltagefrequencyonbarkhausennoisesignal