Kompakti automatisoitu laser-ionisointijärjestelmä

In an experimental nuclear physics off-line systems are often used in situations where acceleration energies are relatively small. Main benefits are low price and meager radiated laboratory enviroments. In this master’s thesis I discuss mostly about automation which was used in our off-line system....

Full description

Bibliographic Details
Main Author: Partanen, Vesa
Other Authors: Matemaattis-luonnontieteellinen tiedekunta, Faculty of Sciences, Fysiikan laitos, Department of Physics, University of Jyväskylä, Jyväskylän yliopisto
Format: Master's thesis
Language:fin
Published: 2011
Subjects:
Online Access: https://jyx.jyu.fi/handle/123456789/36806
_version_ 1826225680597123073
author Partanen, Vesa
author2 Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics University of Jyväskylä Jyväskylän yliopisto
author_facet Partanen, Vesa Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics University of Jyväskylä Jyväskylän yliopisto Partanen, Vesa Matemaattis-luonnontieteellinen tiedekunta Faculty of Sciences Fysiikan laitos Department of Physics University of Jyväskylä Jyväskylän yliopisto
author_sort Partanen, Vesa
datasource_str_mv jyx
description In an experimental nuclear physics off-line systems are often used in situations where acceleration energies are relatively small. Main benefits are low price and meager radiated laboratory enviroments. In this master’s thesis I discuss mostly about automation which was used in our off-line system. The system was built at the Ion Guide Separator On-Line facility (IGISOL) in Jyväskylä University. The automation set up was made with the Phoenix Contacts inline terminals, which were programmed by using the Labview program. The system consists of thermistor, skimmer handling, mirror handling, gasline parts per billion (ppb) mixing and quadrupole mass spectrometer measurement. There were major problems with the control unit of the quadrupole mass spectrometer, hence this project is truly unfinished. On the other hand, the system will be modified for various purposes, so the system was partly tested. Test results show that the system works with low mass-charge particles. I have included quite detailed descriptions about my programs, thus this thesis can be also used as a program manual.
first_indexed 2023-03-22T09:56:58Z
format Pro gradu
free_online_boolean 1
fullrecord [{"key": "dc.contributor.author", "value": "Partanen, Vesa", "language": null, "element": "contributor", "qualifier": "author", "schema": "dc"}, {"key": "dc.date.accessioned", "value": "2011-10-13T17:28:20Z", "language": null, "element": "date", "qualifier": "accessioned", "schema": "dc"}, {"key": "dc.date.available", "value": "2011-10-13T17:28:20Z", "language": null, "element": "date", "qualifier": "available", "schema": "dc"}, {"key": "dc.date.issued", "value": "2011", "language": null, "element": "date", "qualifier": "issued", "schema": "dc"}, {"key": "dc.identifier.other", "value": "oai:jykdok.linneanet.fi:1185384", "language": null, "element": "identifier", "qualifier": "other", "schema": "dc"}, {"key": "dc.identifier.uri", "value": "https://jyx.jyu.fi/handle/123456789/36806", "language": null, "element": "identifier", "qualifier": "uri", "schema": "dc"}, {"key": "dc.description.abstract", "value": "In an experimental nuclear physics off-line systems are often used in situations where acceleration energies are relatively small. Main benefits are low price and meager radiated laboratory enviroments. In this master\u2019s\nthesis I discuss mostly about automation which was used in our off-line system. The system was built at the Ion Guide Separator On-Line facility (IGISOL) in Jyv\u00e4skyl\u00e4 University.\n\nThe automation set up was made with the Phoenix Contacts inline terminals, which were programmed by using the Labview program. The system consists of thermistor, skimmer handling, mirror handling, gasline parts per billion (ppb) mixing and quadrupole mass spectrometer measurement. \n\nThere were major problems with the control unit of the quadrupole\nmass spectrometer, hence this project is truly unfinished. On the other hand, the system will be modified for various purposes, so the system was partly tested. Test results show that the system works with low mass-charge particles.\n\nI have included quite detailed descriptions about my programs, thus this thesis can be also used as a program manual.", "language": null, "element": "description", "qualifier": "abstract", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Submitted using Plone Publishing form by Vesa Partanen (veespepa) on 2011-10-13 17:28:12.623605. Form: Pro gradu -lomake (1 tekij\u00e4) (https://kirjasto.jyu.fi/julkaisut/julkaisulomakkeet/pro-gradu-lomake-1-tekijae). JyX data:", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Submitted by jyx lomake-julkaisija (jyx-julkaisija@noreply.fi) on 2011-10-13T17:28:20Z\nNo. of bitstreams: 2\nURN:NBN:fi:jyu-2011101311542.pdf: 48495970 bytes, checksum: e36883522d76b40e78cb37f970afbe6f (MD5)\nlicense.html: 4989 bytes, checksum: 7a2771c202157805a59d593a980b467a (MD5)", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Made available in DSpace on 2011-10-13T17:28:20Z (GMT). No. of bitstreams: 2\nURN:NBN:fi:jyu-2011101311542.pdf: 48495970 bytes, checksum: e36883522d76b40e78cb37f970afbe6f (MD5)\nlicense.html: 4989 bytes, checksum: 7a2771c202157805a59d593a980b467a (MD5)\n Previous issue date: 2011", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.format.extent", "value": "173 sivua", "language": null, "element": "format", "qualifier": "extent", "schema": "dc"}, {"key": "dc.format.mimetype", "value": "application/pdf", "language": null, "element": "format", "qualifier": "mimetype", "schema": "dc"}, {"key": "dc.language.iso", "value": "fin", "language": null, "element": "language", "qualifier": "iso", "schema": "dc"}, {"key": "dc.rights", "value": "In Copyright", "language": "en", "element": "rights", "qualifier": null, "schema": "dc"}, {"key": "dc.subject.other", "value": "off-line", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "experimental nuclear physics", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "kokeellinen ydinfysiikka", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "automation", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "automaatio", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "Labview", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "quadrupole mass spectrometer", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "kvadrupolimassaspektrometri", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "laser-ionization", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "laser-ionisaatio", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "vacuum", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "tyhji\u00f6", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "gas impurity", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "ep\u00e4puhtaudet", "language": "", "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.title", "value": "Kompakti automatisoitu laser-ionisointij\u00e4rjestelm\u00e4", "language": null, "element": "title", "qualifier": null, "schema": "dc"}, {"key": "dc.type", "value": "master thesis", "language": null, "element": "type", "qualifier": null, "schema": "dc"}, {"key": "dc.identifier.urn", "value": "URN:NBN:fi:jyu-2011101311542", "language": null, "element": "identifier", "qualifier": "urn", "schema": "dc"}, {"key": "dc.type.dcmitype", "value": "Text", "language": "en", "element": "type", "qualifier": "dcmitype", "schema": "dc"}, {"key": "dc.type.ontasot", "value": "Pro gradu -tutkielma", "language": "fi", "element": "type", "qualifier": "ontasot", "schema": "dc"}, {"key": "dc.type.ontasot", "value": "Master\u2019s thesis", "language": "en", "element": "type", "qualifier": "ontasot", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Matemaattis-luonnontieteellinen tiedekunta", "language": "fi", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Faculty of Sciences", "language": "en", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Fysiikan laitos", "language": "fi", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Department of Physics", "language": "en", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "University of Jyv\u00e4skyl\u00e4", "language": "en", "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "Jyv\u00e4skyl\u00e4n yliopisto", "language": "fi", "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Fysiikka", "language": "fi", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Physics", "language": "en", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "dc.date.updated", "value": "2011-10-13T17:28:21Z", "language": null, "element": "date", "qualifier": "updated", "schema": "dc"}, {"key": "dc.type.coar", "value": "http://purl.org/coar/resource_type/c_bdcc", "language": null, "element": "type", "qualifier": "coar", "schema": "dc"}, {"key": "dc.rights.accesslevel", "value": "openAccess", "language": "fi", "element": "rights", "qualifier": "accesslevel", "schema": "dc"}, {"key": "dc.type.publication", "value": "masterThesis", "language": null, "element": "type", "qualifier": "publication", "schema": "dc"}, {"key": "dc.subject.oppiainekoodi", "value": "4021", "language": null, "element": "subject", "qualifier": "oppiainekoodi", "schema": "dc"}, {"key": "dc.subject.yso", "value": "ydinfysiikka", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "automaatio", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "ep\u00e4puhtaudet", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "lasertekniikka", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.format.content", "value": "fulltext", "language": null, "element": "format", "qualifier": "content", "schema": "dc"}, {"key": "dc.rights.url", "value": "https://rightsstatements.org/page/InC/1.0/", "language": null, "element": "rights", "qualifier": "url", "schema": "dc"}, {"key": "dc.type.okm", "value": "G2", "language": null, "element": "type", "qualifier": "okm", "schema": "dc"}]
id jyx.123456789_36806
language fin
last_indexed 2025-02-18T10:54:10Z
main_date 2011-01-01T00:00:00Z
main_date_str 2011
online_boolean 1
online_urls_str_mv {"url":"https:\/\/jyx.jyu.fi\/bitstreams\/53e67e5a-65f7-499a-9001-04143e88f5a9\/download","text":"URN:NBN:fi:jyu-2011101311542.pdf","source":"jyx","mediaType":"application\/pdf"}
publishDate 2011
record_format qdc
source_str_mv jyx
spellingShingle Partanen, Vesa Kompakti automatisoitu laser-ionisointijärjestelmä off-line experimental nuclear physics kokeellinen ydinfysiikka automation automaatio Labview quadrupole mass spectrometer kvadrupolimassaspektrometri laser-ionization laser-ionisaatio vacuum tyhjiö gas impurity epäpuhtaudet Fysiikka Physics 4021 ydinfysiikka lasertekniikka
title Kompakti automatisoitu laser-ionisointijärjestelmä
title_full Kompakti automatisoitu laser-ionisointijärjestelmä
title_fullStr Kompakti automatisoitu laser-ionisointijärjestelmä Kompakti automatisoitu laser-ionisointijärjestelmä
title_full_unstemmed Kompakti automatisoitu laser-ionisointijärjestelmä Kompakti automatisoitu laser-ionisointijärjestelmä
title_short Kompakti automatisoitu laser-ionisointijärjestelmä
title_sort kompakti automatisoitu laser ionisointijärjestelmä
title_txtP Kompakti automatisoitu laser-ionisointijärjestelmä
topic off-line experimental nuclear physics kokeellinen ydinfysiikka automation automaatio Labview quadrupole mass spectrometer kvadrupolimassaspektrometri laser-ionization laser-ionisaatio vacuum tyhjiö gas impurity epäpuhtaudet Fysiikka Physics 4021 ydinfysiikka lasertekniikka
topic_facet 4021 Fysiikka Labview Physics automaatio automation epäpuhtaudet experimental nuclear physics gas impurity kokeellinen ydinfysiikka kvadrupolimassaspektrometri laser-ionisaatio laser-ionization lasertekniikka off-line quadrupole mass spectrometer tyhjiö vacuum ydinfysiikka
url https://jyx.jyu.fi/handle/123456789/36806 http://www.urn.fi/URN:NBN:fi:jyu-2011101311542
work_keys_str_mv AT partanenvesa kompaktiautomatisoitulaserionisointijärjestelmä