fullrecord |
[{"key": "dc.contributor.advisor", "value": "Teerim\u00e4ki, P\u00e4ivi", "language": null, "element": "contributor", "qualifier": "advisor", "schema": "dc"}, {"key": "dc.contributor.advisor", "value": "Miettinen, Arttu", "language": null, "element": "contributor", "qualifier": "advisor", "schema": "dc"}, {"key": "dc.contributor.author", "value": "Repo, Venla", "language": null, "element": "contributor", "qualifier": "author", "schema": "dc"}, {"key": "dc.date.accessioned", "value": "2025-05-20T05:44:17Z", "language": null, "element": "date", "qualifier": "accessioned", "schema": "dc"}, {"key": "dc.date.available", "value": "2025-05-20T05:44:17Z", "language": null, "element": "date", "qualifier": "available", "schema": "dc"}, {"key": "dc.date.issued", "value": "2025", "language": null, "element": "date", "qualifier": "issued", "schema": "dc"}, {"key": "dc.identifier.uri", "value": "https://jyx.jyu.fi/handle/123456789/102456", "language": null, "element": "identifier", "qualifier": "uri", "schema": "dc"}, {"key": "dc.description.abstract", "value": "Tomosynteesi on mammografiamenetelm\u00e4, jonka avulla saadaan poikkileikekuvia\nrinnan rakenteesta. Menetelm\u00e4lle ei ole aiemmin ollut kotimaista laadunvalvontasuositusta, mutta tarve sille on her\u00e4nnyt tomosynteesin kliinisen k\u00e4yt\u00f6n yleistyess\u00e4. \n\nT\u00e4ss\u00e4 ty\u00f6ss\u00e4 perehdyttiin tomosynteesin laadunvalvonnan kotimaiseen ja kansainv\u00e4liseen tilanteeseen sek\u00e4 olemassa oleviin suosituksiin ja laadittiin kansallinen laadunvalvontasuositus yhteisty\u00f6ss\u00e4 useiden sairaaloiden, laitevalmistajien ja S\u00e4teilyturvakeskuksen kanssa. Suositukseen valittujen laadunvalvontatestien sopivuutta arvioitiin eri kriteerien ja mittaustulosten perusteella. Arviointikriteerein\u00e4 olivat muun muassa testin merkityksellisyys, toteutuksen yksinkertaisuus, toistettavuus ja tarvittavien v\u00e4lineiden saatavuus. Testit suoritettiin niiden soveltuvuuden varmistamiseksi viidell\u00e4 eri valmistajan mammografialaitteella. Lopputuloksena valittiin 12 laadunvalvontatesti\u00e4, joita suositellaan toteutettavaksi osana mammografian muuta laadunvalvontaa. Ty\u00f6n perusteella laaditun suosituksen ensimm\u00e4inen versio l\u00f6ytyy liitteest\u00e4 B. Lopullinen versio tullaan julkaisemaan erikseen S\u00e4teilyturvakeskuksen julkaisusarjassa STUK opastaa.", "language": "fi", "element": "description", "qualifier": "abstract", "schema": "dc"}, {"key": "dc.description.abstract", "value": "The purpose of this thesis was to establish national quality control guidelines in tomosynthesis. Tomosynthesis is a pseudo-3D breast imaging method, which hasn\u2019t\npreviously had national quality control guidelines despite its increasing usage.\n\nThe purpose of this thesis was to establish national quality control guidelines in tomosynthesis together with several hospitals, manufacturers and the Finnish Radiation and Nuclear Safety Authority. Based on the current international guidelines for tomosynthesis and national guidelines for 2D-mammography a selection of potential quality control tests were chosen, and their suitability was evaluated based on different criteria, such as the purpose and complexity of the test, and equipment and time required. Measurements were made to confirm these results, and the chosen tests were also executed on five different mammography systems. As a result, 12 quality control tests are recommended to be performed as a part of general quality control in mammography. The first draft of these guidelines can be found from attachment B. The final version will be published separately in the Finnish Radiation and Nuclear Safety Authority\u2019s publication series \"STUK opastaa.\"", "language": "en", "element": "description", "qualifier": "abstract", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Submitted by Paivi Vuorio (paelvuor@jyu.fi) on 2025-05-20T05:44:17Z\nNo. of bitstreams: 0", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.description.provenance", "value": "Made available in DSpace on 2025-05-20T05:44:17Z (GMT). No. of bitstreams: 0\n Previous issue date: 2025", "language": "en", "element": "description", "qualifier": "provenance", "schema": "dc"}, {"key": "dc.format.extent", "value": "85", "language": null, "element": "format", "qualifier": "extent", "schema": "dc"}, {"key": "dc.language.iso", "value": "fin", "language": null, "element": "language", "qualifier": "iso", "schema": "dc"}, {"key": "dc.rights", "value": "In Copyright", "language": null, "element": "rights", "qualifier": null, "schema": "dc"}, {"key": "dc.subject.other", "value": "3D-mammografia", "language": null, "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.subject.other", "value": "rintojen r\u00f6ntgenkuvantaminen", "language": null, "element": "subject", "qualifier": "other", "schema": "dc"}, {"key": "dc.title", "value": "Tomosynteesin laadunvalvonta", "language": null, "element": "title", "qualifier": null, "schema": "dc"}, {"key": "dc.type", "value": "master thesis", "language": null, "element": "type", "qualifier": null, "schema": "dc"}, {"key": "dc.identifier.urn", "value": "URN:NBN:fi:jyu-202505204390", "language": null, "element": "identifier", "qualifier": "urn", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Matemaattis-luonnontieteellinen tiedekunta", "language": "fi", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.faculty", "value": "Faculty of Sciences", "language": "en", "element": "contributor", "qualifier": "faculty", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Fysiikan laitos", "language": "fi", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.department", "value": "Department of Physics", "language": "en", "element": "contributor", "qualifier": "department", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "Jyv\u00e4skyl\u00e4n yliopisto", "language": null, "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.contributor.organization", "value": "University of Jyv\u00e4skyl\u00e4", "language": null, "element": "contributor", "qualifier": "organization", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Fysiikka", "language": "fi", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "dc.subject.discipline", "value": "Physics", "language": "en", "element": "subject", "qualifier": "discipline", "schema": "dc"}, {"key": "dc.type.coar", "value": "http://purl.org/coar/resource_type/c_bdcc", "language": null, "element": "type", "qualifier": "coar", "schema": "dc"}, {"key": "dc.rights.copyright", "value": "\u00a9 The Author(s)", "language": "fi", "element": "rights", "qualifier": "copyright", "schema": "dc"}, {"key": "dc.rights.accesslevel", "value": "openAccess", "language": null, "element": "rights", "qualifier": "accesslevel", "schema": "dc"}, {"key": "dc.type.publication", "value": "masterThesis", "language": null, "element": "type", "qualifier": "publication", "schema": "dc"}, {"key": "dc.subject.yso", "value": "laadunvalvonta", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.subject.yso", "value": "tomosynteesi", "language": null, "element": "subject", "qualifier": "yso", "schema": "dc"}, {"key": "dc.rights.url", "value": "https://rightsstatements.org/page/InC/1.0/", "language": null, "element": "rights", "qualifier": "url", "schema": "dc"}, {"key": "dc.description.accessibilityfeature", "value": "unknown accessibility", "language": "en", "element": "description", "qualifier": "accessibilityfeature", "schema": "dc"}, {"key": "dc.description.accessibilityfeature", "value": "ei tietoa saavutettavuudesta", "language": "fi", "element": "description", "qualifier": "accessibilityfeature", "schema": "dc"}]
|